PLEASE VISIT OUR SOLAR PAGE ..CLICK ON TOP "SOLAR"

Wednesday, August 24, 2011

അസംബിള്‍ഡ് F M ബോര്‍ഡ്

FM Module with USB Function


The VIRE-FM 01C FM –USB Module is available as ready made assembled board. Its output can be connected to power amplifier or into the amplifier of VCD player, Car stereo etc. The module has the following important features:

Item .No.VIRE-FM-003-01
  • FM Channels 87.5 – 108 MHz

  • Song number display

  • Song selection mode

  • Auto channel scan and save provision

  • Digital volume level display

  • Forward and backward selection

  • Volume Up /down buttons

The circuit board is available as kits with connecting wires. It is necessary to connect Remote Sensor, USB socket and Amplifier with speaker.
The circuit requires 5 Volt regulated power supply.
Connections
On the PCB, there are markings for wire connections and wire sets are provided along with the kit. The markings on the back of the PCB indicates:
  • IR Sensor TSOP 1738 connection

  • G-Ground – Pin1 of sensor

  • R1 – Output of Sensor-Pin 3 of sensor

  • 3.3 V Supply – Pin 2 of sensor

Connect the wires connected to these points to the sensor:
USB Connection
1. GND
2. DP
3. DM
4. 5V- 5 Volt will be available from the board itself
Output to Amplifier
L – Left channel
G – Ground
R – Right channel
Volume control
Use a 10 K Lin dual volume control between the output lines (L and R) of the module and the amplifier. Set minimum volume (2 to 4) in the module using remote and adjust 10 K pot to get clear sound from the speaker. Then increase the volume using remote to the required level. The module can give 1 to 50 range volume.
Antenna
Antenna is necessary if the signal strength is weak .Connect 30 cm plastic wire to the point ANT on the PCB
5 Volt regulated power supply is necessary for the circuit. Make a regulated power supply with IC 7805 with 1000 uF filter capacitor. If the power supply is not well regulated or with ripples, performance of the circuit will be poor.
Remote less operation
On the PCB, connections V+, PM, CH V-, P etc are given to connect membrane switches for manual operation.



 ഈ ലേഖനം എഴുതിയത്








D. Mohankumar