PLEASE VISIT OUR SOLAR PAGE ..CLICK ON TOP "SOLAR"

Sunday, February 10, 2013

സീലിംഗ് ഫാനിന്റെ ഉള്ളുകള്ളികള്‍

      സീലിംഗ് ഫാനിന്റെ ഉള്ളുകള്ളികള്‍
നിങ്ങള്‍ ഒരു ഫാന്‍ മോട്ടോര്‍ തുറന്നു നോക്കിയിട്ടുണ്ടോ?  അത് ഒരു ലളിതമായ ബ്രഷ് ലെസ്‌  A/C ഇന്‍ഡക്ഷന്‍ മോട്ടോര്‍ ആണ്  മോട്ടോറിന്റെ ഭാഗങ്ങള്‍ ചിത്രം നോക്കി മനസിലാക്കുക. പ്രധാന ഭാഗങ്ങള്‍. C: ബോള്‍ ബെയറിംഗ് D: സ്റ്റേറ്റര്‍ E: ആര്‍മേച്ചര്‍, G:കപ്പാസിറ്റര്‍, H: കണക്റ്റര്‍
Also, look at the other image that shows the cross section of a motor.  You would notice that there are 4 wires coming out the motor.  Two pairs of wire, with one pair as the starting coil and the another pair for the running coil.  In general, all single phases induction motors have two coils (starting coil, running coil).  Using a capacitor, an artificial phase difference is created between the fields created by the starting and running coils.  The phase difference triggers movement of the armature.  When the armature reaches a particular speed, using a centrifugal switch, the connection to the starting coil is disconnected and the entire fans runs with just one coil.

Although there are four terminals, you would notice 3 terminals are emitted out, with the starting and running coils connected back-to-back.  Let’s say S1,S2 are the terminals of starting coil and R1,R2 are the terminals of the running coil.  To get 3 terminals out of the fan motor, S2 and R2 are shorted. 
Now, you just see 3 terminals; how do you find which terminal is starting, which one is ending and which one is shorted?  Easy.  Using a simple multimeter, you can find it out.
Let’s say you see terminals A, B, C. Our aim is to find which one of these are S1, R1, S2R2.  Now, let’s measure the resistance between A-B, call it X.  Likewise measure the resistance B-C as Y and A-C as Z.  If you would notice X < Y < Z, you would also notice that Z = Y+X.  Which mean, A-C is action A-B+B-C, that’s why the resistance was additive, also the terminal B is S2R2.  The challenge now is to find what is A and what is C.   As we’d notice A-B=X < B-C=Y, we can confirm that terminal A is starting coil S1 and terminal C is running coil R1.  The reasoning is that; starting coil resistance will be less than running coil resistance.

2 comments: